30
Figure 2.3: Connection diagram
TIP:
For very large objects, or objects with deep cavities, a smaller camera angle may be necessary.
Angles less than 20° result in reduced scan quality (noise, inaccuracies). A very large camera angle
(> 30°), may improve the scan quality a little, but is only suitable for very at objects. Large camera
angles are usually impractical and reduce the depth of the measurement range.
2.3. Connection
Connect the camera, the projector and the DAVID USB ash drive according to the wiring diagram to
your computer (Fig. 2.3). To connect the projector to your computer, you can use HDMI (recommended)
or VGA.
2.4. Installing the Camera Driver
Even if Windows installs drivers automatically, please install the supplied drivers:
1 Connect the USB ash drive to your PC, then select ”Browse“ or Explorer / My Computer.
2 Start ”Install_DAVID-CAM-3 M_Driver“ (administrator rights required).
3 Follow the instructions on the screen.